Production LVD™ platform GaN
PDC-6012 Series

60 V → 12 V high-density GaN converter

A 1.8 kW gallium-nitride point-of-load converter that bridges 48 V and 60 V distribution to legacy 12 V loads — at extreme power density and near-flat efficiency.

1.8kW
Rated power
98.6%
Peak efficiency
8.5kW/L
Power density
150A
Output current
Overview

The 48 V-to-12 V bridge, done right

As vehicles move primary distribution to 48 V, the 12 V net still feeds lighting, ECUs, and legacy actuators. The PDC-6012 is a non-isolated, multiphase synchronous buck built on gallium-nitride HEMTs and powder-core inductors. Six interleaved phases switch fast and ripple-cancel, yielding a compact, near-flat efficiency curve and clean 12 V output — with optional bidirectional boost for 12 V-to-48 V support.

  • Exceptional 8.5 kW/L power density in a sealed conduction- or liquid-cooled package.
  • 98.6% peak efficiency, held within a point across most of the load range.
  • Six-phase interleaving for low ripple and fast transient response.
  • CAN-FD and PMBus control, with the same diagnostics model as the HVX™ converters.
Power architecture

Multiphase synchronous buck

60 V INPUT EMIFILTER GaN 6-PHASE SYNCHRONOUS BUCK · POWDER-CORE L Φ1Φ2Φ3 Φ4Φ5Φ6 OUTPUTFILTER 12 V OUT DIGITAL CONTROLLER · CAN-FD · PMBus Interleaved PWM · ISO 26262 ASIL B capable NON-ISOLATED · COMMON GROUND
Specifications

Technical data

Input
Nominal input voltage60 VDC (48 V systems supported)
Operating input range36 – 75 VDC
Max continuous input current32 A
Reverse-polarity protectionYes
Output — 12 V
Nominal output voltage12 VDC
Adjustable output range9 – 16 VDC
Rated continuous power1.8 kW
Peak power (10 s)2.2 kW
Continuous output current150 A
Output voltage accuracy± 1 %
Output ripple & noise< 60 mV pp
Conversion & performance
TopologyNon-isolated 6-phase synchronous buck, GaN HEMT
Switching frequency500 kHz – 1 MHz per phase (interleaved)
Power directionBidirectional (optional boost)
Peak efficiency98.6 %
Weighted efficiency98.0 %
IsolationNon-isolated (common ground)
Standby power< 2 W
Mechanical & environmental
Dimensions (L × W × H)120 × 80 × 22 mm
Volume0.21 L
Mass0.45 kg
CoolingConduction baseplate or liquid cold-plate
Coolant inlet temperatureup to 65 °C
Operating temp (baseplate)−40 to +105 °C
Storage temperature−40 to +125 °C
EnclosureDie-cast aluminum
Ingress protectionIP6K7 / IP6K9K
Vibration & shockper ISO 16750-3
Control & communication
Primary interfaceCAN 2.0B / CAN-FD (ISO 11898)
Secondary interfacePMBus (optional)
Control modesCV, CC, droop
TelemetryV/I in & out, temps, status, faults
Enable / inhibitHardware + CAN
Firmware updateCAN bootloader
Protection & functional safety
Input protectionOVP, UVP, reverse polarity
Output protectionOVP, OCP, short-circuit
Thermal protectionOTP with foldback
Functional safetyDeveloped per ISO 26262, ASIL B capable
Compliance & qualification
EMC (emissions)CISPR 25 Class 5
EMC (immunity)ISO 11452, ISO 7637-2
EnvironmentalISO 16750-1…5
ComponentsAEC-Q100 / Q101
Manufacturing processIATF 16949
Qualification statusReleased — reports under NDA

Preliminary specification. Values are typical at 25 °C and nominal input unless otherwise stated, and are subject to change without notice. Derating curves and full qualification data are provided in the datasheet under NDA.

Ordering information

Part-number configurator

Configure a variant using the field codes below, or contact engineering for a custom build.

PDC-6012-18C-CF-S-A1
FieldCode
Power class18 = 1.8 kW
CoolingC = conduction · L = liquid cold-plate
InterfaceCF = CAN-FD · CP = CAN-FD + PMBus
DirectionS = single (buck) · B = bidirectional
Revisione.g. A1 (current production)

Request the PDC-6012 datasheet